National Changhua University of Education Institutional Repository : Item 987654321/11929
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 6507/11669
造访人次 : 30075737      在线人数 : 698
RC Version 3.2 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 进阶搜寻

jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.ncue.edu.tw/ir/handle/987654321/11929

题名: Investigation of tumor cell targeting of a dendrimer nanoparticle using a double-clad optical fiber probe
作者: Thomas, Thommey P.;Kotlyar, Alina;Cao, Zhengyi;Majoros, Istvan J.;James R. Baker, Jr.;Ye, Jing-Yong;Chang, Yu-Chung;Theodore B. Norris
贡献者: 電機工程學系
关键词: Bio-optics;Cancer;Cellular biophysics;Fibre optic sensors;Fluorescence;Laser applications in medicine;Light absorption;Light scattering;Nanobiotechnology;Nanoparticles;Tumours;Two-photon spectra;Dendrimer;Nanotechnology;Double-clad optical fiber;Two-photon excitation;Cancer targeting
日期: 2008-02
上传时间: 2012-07-03T01:48:16Z
出版者: SPIE
摘要: Fluorescence quantification in tissues using conventional techniques can be difficult due to the absorption and scattering of light in tissues. Our previous studies have shown that a single-mode optical fiber (SMF)–based, two-photon optical fiber fluorescence (TPOFF) probe could be effective as a minimally invasive, real-time technique for quantifying fluorescence in solid tumors. We report improved results with this technique using a solid, double-clad optical fiber (DCF). The DCF can maintain a high excitation rate by propagating ultrashort laser pulses down an inner single-mode core, while demonstrating improved collection efficiency by using a high–numerical aperture multimode outer core confined with a second clad. We have compared the TPOFF detection efficiency of the DCF versus the SMF with standard solutions of the generation 5 poly(amidoamine) dendrimer (G5) nanoparticles G5-6TAMRA (G5-6T) and G5-6TAMRA-folic acid (G5-6T-FA). The DCF probe showed three- to five-fold increases in the detection efficiency of these conjugates, in comparison to the SMF. We also demonstrate the applicability of the DCF to quantify the targeted uptake of G5-6T-FA in mouse tumors expressing the FA receptor. These results indicate that the TPOFF technique using the DCF probe is an appropriate tool to quantify low nanomolar concentrations of targeted fluorescent probes from deep tissue.
關聯: Journal of Biomedical Optics, 13(1): 014024
显示于类别:[電機工程學系] 期刊論文

文件中的档案:

档案 大小格式浏览次数
2050201110001.pdf79KbAdobe PDF526检视/开启


在NCUEIR中所有的数据项都受到原著作权保护.

 


DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈