National Changhua University of Education Institutional Repository : Item 987654321/1535
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 6507/11669
造访人次 : 29617884      在线人数 : 305
RC Version 3.2 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 进阶搜寻

jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.ncue.edu.tw/ir/handle/987654321/1535

题名: Determination of tertiary amines based on pH junctions and field amplification in capillary electrophoresis with electrochemiluminescence detection
作者: Sreedhar, M.;Lin, Y.-W.;Chang, H.-T.
贡献者: 化學系
日期: 2005
上传时间: 2010-11-10T06:30:47Z
摘要: A stacking approach based on pH junction and field amplification has been developed for determining amines by capillary electrophoresis (CE) with electrochemiluminescence (ECL) detection. A two-electrode configuration was employed with an indium/tin oxide-coated glass as a working electrode and a platinum wire as a pseudoreference electrode. The ECL system also contains a flow cell (poly(dimethylsiloxane)-aluminum oxide) that was made from a mixture of Sylgard 184 silicone elastomer, a curing agent, and aluminum oxide. In order to improve the sensitivity of the present CE-ECL system using tris(2,2'-bipyridyl) ruthenium(II) (Ru(bpy)(3) (2+)), a stacking approach based on pH junctions and field amplification has been tested for the analysis of triethylamine (TEA), tripropylamine (TPA), and tributylamine (TBA). Once amines (cations) prepared in citric acid solution (pH < 4.0) migrate towards the background electrolyte (15 mM sodium borate at pH 8.0), they slow down and are stacked at the boundary as a result of deprotonation and decreases in the electric field. By applying hydrodynamic injection of the sample for 60 s, this method provides the concentration limits of detection (signal-to-noise ratio = 3) of 24, 20, and 32 nM for TEA, TPA, and TBA, respectively. The results indicate that the stacking CE-ECL system is better than CE-ECL systems using a two-electrode configuration and comparable to those using a three-electrode configuration. The potential applicability of the new and low-cost CE-ECL system has been demonstrated by the determination of 1.0 microM lidocaine, a local anesthetic drug, in urine without any tedious sample preparation.
關聯: Electrophoresis, 26, 2984-2990
显示于类别:[化學系] 期刊論文

文件中的档案:

没有与此文件相关的档案.



在NCUEIR中所有的数据项都受到原著作权保护.

 


DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈